Home > Products > UPS power supply

Three in and three out 1 0 - 1 2 0 K VA Series

Brand:
Model:
Updated: 2014/8/22
  • Product description
  • Scope of application
  • Product features
  • Technical parameters

With LCD Chinese LCD display function of Renda 10KVA~120KVA series, is Renda company for users of enterprise-level key load power supply needs and specially launched 10KVA~20KVA power band in line UPS products, it inherits the excellent quality of Renda products, but also has humanized management functions, can provide high-reliability power protection for users' enterprise-level servers, small and medium-sized local area networks, small computer rooms and other precision electronic instruments.

Renda UPS power supply power frequency three in three out 10-120KVA application field:

 
Renda power frequency three-in, three-out 10-120KVA uninterruptible UPS power supply inherits the excellent quality of Renda products, and has humanized management functions, which can provide high-reliability power protection for users' enterprise-level servers, small and medium-sized LANs, small computer rooms and other precision electronic instruments.

 ● Touch screen

 
Powerful Chinese/English display interface: using full digital touch screen large screen LCD Chinese and English display, the display content can be selected and set in Chinese/English, and the operating status, operating procedures, data collection, troubleshooting data and other contents are clear at a glance;
 
● Advanced working mode
 
Double conversion online design, so that the output of UPS is a pure sine wave power supply with frequency tracking, phase-locked voltage regulation, noise filtering, and no interference from grid fluctuations, providing more comprehensive protection for the load.
 
Output zero conversion time, to meet the high standard requirements of precision equipment for power supply.
 
Adopt six-pulse rectification to improve the utilization rate of electric energy, greatly eliminate the harmonic pollution of UPS to the mains power grid, and reduce the operating cost of UPS.
 
● Economic Operating Mode (ECO) function
 
When the input mains power is within a fixed range, the energy is directly supplied to the load by the input mains power, and the inverter is in a waiting state; When the input mains power is abnormal, it is immediately converted to inverter power supply. ECO operation mode can be efficient and energy-saving and reduce user costs.
 
●Optimize the functional design of the battery pack
 
Through innovative optimization of battery pack function design, whether it is a standard model or a long-delay model, it saves battery consumption more than traditional design solutions under the condition of meeting the same backup time.
 
●Strong environmental adaptability
 
Wide voltage range, avoid frequent switching to battery power supply when the grid voltage changes greatly, and adapt to areas with harsh power environment.
 
Wide input frequency range to ensure that all kinds of fuel generators can work stably and meet the requirements of users for the use of oil turbines.
 
● Reliable protection function
 
With the function of booting self-diagnosis, it can find the hidden fault of UPS in time and prevent problems before they occur.
 
With input over-under-voltage protection, output over-current, overload, short-circuit protection, PFC and inverter overheating protection, battery overcharge and under-voltage warning protection and other protections to ensure the stability and reliability of system operation.
 
With automatic bypass function, when the output is overloaded or faulty, it can be continuously transferred to the bypass working state by the mains to continue to supply power to the load.
 
With DC start function, UPS can be directly started in the state of no mains power to meet the emergency needs of users.
 
●Rich options, intelligent management
 
Chinese LCD interface can display load, battery capacity, input and output parameters and fault information, which is convenient for user operation and maintenance management.
 
· RS232 local monitoring. UPS is equipped with RS232 interface as standard, and local monitoring can be easily carried out through the included monitoring software.
 
Optocoupler dry contact. Through the DB9 dry contact interface, the main abnormal information of the UPS can be led out through the dry contact, and the dry contact signal is isolated by optocoupler, and the user can easily use these signals to control some strong and weak current equipment.
 
· SNMP card/centralized monitoring card (optional). Through the optional SNMP card, the UPS can be connected to Ethernet for remote monitoring. The centralized monitoring card can realize simultaneous monitoring of multiple machines and record the events and alarms of each machine. SNMP card/centralized monitoring card is a goldfinger board structure, users can invest in installments and purchase when needed.
 
Alarm relay card (optional). Up to 6 alarm relay outputs provide a high-capacity interface for easy connection of extended alarm devices.
 
Parallel interface module (optional). Through the optional parallel interface module, 4 machines can be powered in parallel.
 
● Fault isolation
 
The maintenance bypass module can be separated, and the maintenance bypass module can be taken out online when UPS fault needs to be repaired, while the output load is maintained without interruption.

."

Renda UPS power frequency three in and three out 10-120KVA (technical indicators).
models RDNU3310 RDNU3315 RDNU3320 RDNU3330 RDNU3340 RDNU3360 RDNU3380 RDNU33100 RDNU33120
>rated capacity 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 60KVA/48KW 80KVA/64KW 100KVA/80KW 120KVA/96KW
rated voltage 380V three-phase four-wire
rated frequency 50/60Hz
AC input  
voltage range 380V three-phase ±20%
frequency range 50/60Hz (auto-detection)±5%.
soft start 0-100%5sec
power factor ≥0.8
bypass input  
voltage range 380V±15% three-phase +N
frequency range 50/60Hz (auto-detection)±5%.
inverter bypass (overload)0ms
output  
voltage accuracy 220V±1% (steady-state load), 220V±3% (load fluctuation).
frequency accuracy 50/60Hz±0.05Hz (battery powered).
power factor 0.8 (lag).
waveform distortion linear load <3%, nonlinear load <5%.
steady-state response time <10ms
overload capacity 110/125/150% rated current 300 seconds/10 seconds/1 second
battery  
nominal battery voltage 360V or 384V (optional).
float charge voltage 405V or 432V 486 540
cutoff voltage 315V or 336V 360 400
maximum discharge current 28A 42A 56A 85A 113A 169A 225A 222A 240A
charging current 0.2AXC10
panel display  
display LEDLCD display
alarm audible and visual alarm
protection UPS overcurrent, short circuit, battery low voltage, overtemperature
work environment  
temperature 0℃~40℃
humidity 0~95% non-condensing
storage temperature minus 25~70°C (without battery).
noise 60~65dB
physical properties  
net weight (KG). 210 224.7 230 282 330 440 555 860 900
gross weight (KG). 226 251.5 251.5 389.5 447.5 552.3 700 900 960
size (MM). 305X586X850 555X727X1210 800X720X1390 1115X730X1400

 

 

 