Home > Products > UPS power supply

1-3KVA 100/110/120Vac Online high-frequency UPS

Brand: RENDA
Model: RDD1-3K(L)
Updated: 2016/5/18
  • Product description
  • Scope of application
  • Product features
  • Technical parameters

Excellent performance, simple appearance, perseverance, online double transformation design, DSP digital technology, illustrating the integration of cutting-edge technology and traditional products. It is the preferred product for small and medium-sized servers and computer rooms.

  ◆ The application of advanced DSP digital control technology makes the performance of UPS more stable and the quality more superior.

  ◆ The load power factor is 0.8, which is suitable for the development trend of electrical equipment and has stronger load capacity.

  ◆ Active input power factor correction (PFC), input power factor up to 0.98 or more

◆ Wide input voltage frequency range,

extremely wide input voltage and frequency range, adapt to remote areas with very harsh power environment.  

  ◆ Can be matched with generator.

  ◆ Cold start function.

  ◆ Zero switching, effectively ensuring the safety and reliability of load operation.

  ◆ Powerful monitoring, standard RS232 communication interface and intelligent slot, expandable SNMP card, RS485, AS400 card, EMD environmental monitor, etc.

Product model
Technical characteristics and parameters
RDD1K
RDD1KL
RDD2K
RDD2KL
RDD3K
RDD3KL
Rated output capacity
1000VA/800W
2000VA/1600W
3000VA/2400W
Communication
Enter
Input method
Single-phase grounding
Rated voltage
100/110/120Vac
Rated frequency
50Hz
Input voltage range
85~145VAC±5
Input frequency range
(45~55)±0.5Hz
Bypass voltage
80VAC×(1±5%)~145VAC×(1±5%)
Battery
Enter
Battery pack voltage
24/36/48VDC
48/72/96VDC
48/72/96VDC
Number of battery units
2/3/4
4/6/8
4/6/8
Fallback time (half/full).
Half load≥ 10 minutes, full load ≥5 minutes (standard type).
The maximum inrush current is input at power-on
< 150% of rated current
Battery charging time
5 hours to 90% (standard type).
Depends on external battery pack capacity (long-lasting type).
 
Communication
Output
 
Output mode
Single-phase grounding
Output voltage
100/110/120Vac±3% (inverter output).
Output frequency
50±5Hz (when AC input is normal).
50Hz±1% (when AC input is abnormal).
Dynamic voltage transients
<5%.
Dynamic transient recovery time
< 60ms
Waveform
Sine wave THD <3% (linear load).
Sine wave THD <8% (nonlinear load).
Output power factor
0.8
Overload capacity
The 130% load lasts for not less than 30s, and the recovery point is 90% load
Output current peak factor
3:1
Inverter bypass transition time
< 4ms
Communication and monitoring functions
RS232 (485), dry node, smart slot (expandable SNMP, SMS and other monitoring methods).
Audio noise
< 55dB (1 meter).
Weight (kg).
12
6.5
23
10.5
28
11.5
Size (W*D*H).
145×220×355
190×318×433
190×318×433
? 1991-2024 Renda Group All Rights Reserved.  粵ICP備12015448號